Product Details

MCC - Single Use PP, PES, PVDF, Nylon and Glass Fiber Capsules
Brand MasterCap Compact
Masterfilter MasterCap MCC (compact design) capsule filters are used for removal of micro-organisms and fine particles from liquids. Made of polypropylene and high-performance filtration media such as PP, PES, PTFE, PVDF, Nylon and glass fiber. They are the ideal filters to satisfy the highest standards in a broad range of applications. It is especially designed for self-contained assemblies in pharmaceutical, biologicals, chemicals and food and beverage. No adhesives or glue are used in manufacturing and all bonding is by thermal welding
Features Benefits
- Single-use filtration systems save cleaning time and validation cost
- Available in 5" and 6.5" lengths
- No housing maintenance required
- High throughtput
- Available in pre-sterilized packages
Markets
- Pharmaceuticals and Biologicals
Technical Specification
Materials of construction
Filter media: PP, PES, PVDF, PTFE, NYLON and Glass Fiber
Out shell: Polypropelene
Sealing: Thermal bonding
Operating parameters
Max. operating pressure: 5.0 bar at 20 °C
Max. operating temperature: 40 °C
Autoclave: Recommended 50 cycles for 30 minutes at 130 °C
Applications
- Fermentation
- LVP (Large Volume Parenterals)
- SVP (Small Volume Parenterals)
- Pharmaceutical Water Treatment
- Ophthalmics
- API (Active Pharmaceutical Ingridients)
Filter Properties
- Bacterial Endotoxin: Aqueous extraction of autoclaved filter contains < 0.25 EU/ml as determined by Limulus Amebocyte Lysate (LAL), USP <85>
- Non-Fiber Releasing: Component materials meet the criteria for a “Non-fiber-releasing filter” as defined in 21 CFR 210.3 (b) (6)
- Component Material Toxicity: Meet the requirements of USP <87> In Vitro Cytotoxicity Test and criteria of USP <88> Biological Reactivity Test for Class VI-121 °C plastics
- TOC/Conductivity at 25 °C: Autoclaved filter effluent meets the USP <643> for Total Organic Carbon and USP <645> for Water Conductivity per WFI requirements after a UPW flush of specified volume
- Particle Shedding: Autoclaved filter effluent meet the USP <788> for large volume injection
- Indirect Food: Additive all component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182 and EN framework regulation 1935/2004/EC
Product Document
Name | Size | |
---|---|---|
![]() | MasterCap - MCC Single Use Capsule Filters (english) | 224 KB |