LCFG Lenticular Module Housings

The Masterfilter LCFG enclosed filter housings consisting of a bottom part with three legs and a detachable housing dome. The bottom part with the inlet and outlet socket contains the centering and mounting unit for holding the lenticular filter with a flat adapter or double O-ring adapter type.

The connection between the flat bottom part and the housing dome is designed through a quick closure device like V-band clamp or Rathermann clamp. The module filter housings are available in different sizes and designs.

Features

  • Closed systems ensures product purity and no product losses
  • Requires less space than classified filtration due to vertical design
  • Maximum reliability against product contamination
  • Maximum operating safety due to specific design
  • Available with Rathmann styled bolting clamps or V-band clamp closure options
  • Can be sterilized by autoclaving or steam sterilization or disinfection with hot water or chemicals

Typical Applications

  • Chemicals
  • Cosmetics
  • Food and beverage
  • Pharmaceuticals
  • Biopharmaceuticals

Technical Parameters

  • No. of Elements: 1 to 4
  • Filter connection: Double open end or Code 7
  • Filter diameter: 12 or 16 inch
  • Inlet / Outlet: 2” TC (DIN32676-C)
  • Surface inside: Ra < 0.4 µm electropolished or < 0.8 µm mech. polished
  • Surface outside: Ra < 0.8 µm mech. polished
  • Connection Top: 1.5” TC (DIN32676-C)
  • Drain (in/out): 1.5” TC (DIN32676-C)
  • Sealing: Silicone (FDA/USP VI)
  • Max. Pressure rating: 10 bar
  • Max. Design temperature: 130 °C
  • Material of construction: 316L
  • Design standard: ASME SEC VII DIV1 CE PED, ATEX